Prior to requesting a quotation, a Dia 10mm Titanium Rod in Medical must conform to the appropriate grade, standard, tolerance, and documentation. For implant parts, US purchasers often choose Grade 23 (Ti-6Al-4V ELI) under ASTM F136, with a material test certificate and heat-lot traceability. Then check surface finish, length, and import documentation, and compare total landed cost instead of price per kilogram. This tutorial will describe the specification, evaluation, and importation of 10mm medical titanium bar stock. I also mention what we are providing at Shaanxi CXMET Technology Co., Ltd.
|
|
|
10 mm medical-grade titanium rod: A circular bar with a 10 mm nominal diameter. Mills produce it in the form of cold-worked, ground, polished, or cut-to-length. It is widely used by OEM’s as CNC-ready stock for orthopedic nails, screws, spinal components, dental posts, and surgical tools. Typical materials include commercially pure grade 2 and grade 4 under ASTM F67, and Ti-6Al-4V grade 5 or grade 23 per ASTM B348 or ASTM F136. Include tolerance, straightness, length, end condition, and roughness, since the nominal dimension is not the only definition of the product. “Medical grade” means nothing without test records to back it up.
Titanium’s position in medicine is based on its corrosion resistance, its low density of 4.43 g/cm³ for Ti-6Al-4V ELI, and its extensive clinical track record. A passive layer of oxide is formed on the surface, resisting bodily fluids, moisture, and exposure to chlorides. The elastic modulus of Ti-6Al-4V is around 110 GPa, much less stiff than stainless steel with an elastic modulus of 190–200 GPa. This decreased stiffness is associated with poorer stress shielding in bone in biomaterials evaluations. Chemical inclusions, machining residue, surface cleanliness. Biocompatibility is still Common methods include steam, ethylene oxide, and plasma sterilization. Each final gadget has its own evaluation.
Our Dia 10mm Titanium Rod In Medical is manufactured from Gr. 23 titanium (Ti-6Al-4V ELI) and is compliant with ASTM F136, ISO 5832-3 & AMS 4930. Typical parameters include a tensile strength of not less than 860 MPa, a yield strength of not less than 795 MPa, an elongation of not less than 14%, and a hardness close to 35 HRC. We can offer lengths from 100 mm to 1000 mm or cut to your design with tolerances from h7 to h9 and a polished or machined surface. Our stock range comprises Dia 3–40 mm rods. 1 meter of 10 mm rod weighs about 0.35 kg (78.5 cm³ × 4.43 g/cm³); hence our 10 KG MOQ is approx. 28 meters. Our product data also shows Gr5 stock under ASTM B348; thus, please include the grade on your RFQ.
Grade 2 is well ductile and formable and hence is suitable for chosen instruments as well as non-load-bearing parts. Grade 5 gives more strength to structural parts. Grade 23 has lower limits of oxygen, nitrogen, carbon, and iron than Grade 5, which enhances ductility and fracture toughness, and is typically chosen by engineers for implants. This grade restricts oxygen to 0.13% and iron to 0.25% as per ASTM F136. Before approving a Dia 10mm Titanium Rod in Medical order, verify the specification, chemical, mechanical data, and heat-lot number against your design and regulatory file.
4.43 g/cm^3 is the density of titanium. 316L stainless steel is about 8 g/cm^3, and cobalt-chrome alloys are much denser. The weight difference is a concern for implants and portable tools. But stainless steel could still prevail on cost or rigidity for certain instruments. Cobalt-chrome is very robust and wear-resistant, yet difficult to process. Don’t simply compare the price per kg; compare lifetime cost including machining time, tool wear, scrap, sterilization behavior, and paperwork. You may estimate rod weight by multiplying volume by density, allowing you to compare bids from various providers on the same basis.
Medical teams make this diameter into machine bone fixation and fracture repair parts, orthopedic nails and screws, spinal implants and plates, dental implants and root posts, surgical cutting guides, and joint reconstruction components. It is also used by device manufacturers for external fixator bars and for heavy-duty instrument handles and shafts. The 10 mm size allows for lathe-turned nails with minimum wastage, and its resistance to repeated autoclaving maintains instrument functionality. A Dia 10mm Titanium Rod in a medical project might entail saline or acidic bodily fluids, load-bearing application, and long-term implantation. Your final design and assessment will determine whether it is suitable.
The surface condition influences cleanability, fatigue performance, corrosion behavior, and coating adherence. We work rods by rolling and grinding and may add pickling, polishing, or sandblasting on request. Our tolerance is h7 to h9 or as you request. Swiss-type CNC lathes with tighter ground tolerances run bars via guide bushings. Titanium machines best with sharp tooling, stable coolant, regulated heat, and efficient chip evacuation. In your buy specification, you should include diameter and length tolerance, straightness, concentricity, end squareness, chamfers, and roughness. And when you require near-finished blanks, we thread, drill, and shape rods.
Ask for a mill test report or material test certificate that shows grade, specification, chemical, mechanical characteristics, heat number, dimensions, and inspection data. What is a certificate of conformity? What is a third-party report? What is a manufacturer certificate? Learn the differences. ISO 13485 demonstrates that a supplier has a quality system for medical devices; however, it does not authorize a particular material. Traceability should connect the raw material heat to the records of manufacturing, inspection, packing, and transportation so you can trace an issue or recall. With every purchase, we provide traceability and compliance certifications and test results.
The typical chemical requirements for grade 23 bar purchasers include ICP-OES, ultrasonic testing under AMS 2631 Class A1, microstructure review for alpha case, tensile testing per ASTM E8, and laser-micrometer diameter checks. Ultrasonic testing will identify subsurface voids or inclusions that may be the origin of a fatigue fracture in an implant. Microstructure tests indicate an equiaxed alpha-beta structure. Inform us about the testing your quality team needs for your Dia 10mm Titanium Rod In Medical buy, and we will check what we can include in the report. Getting these tests nailed down early will stop arguments during entry inspection.
A concise request for quote avoids days of back and forth. Diameter (10 mm), Titanium grade, ASTM or ISO standard, Length, Tolerance, Surface finish, Quantity, Certificate required, Packaging, Destination, Incoterms. Tell us whether you want a stocked rod, made-to-order rod, cut blank or machined item. Specify the intended function, such as implant, instrument or prosthetic component. Please also include your expected demand, as repeat volume influences manufacturing planning. We bundle rods in conventional wooden containers and check requirements before we quote. Dia 10mm Titanium Rod In Medical Inquiry
For US import you may anticipate a commercial invoice, Packing List, Certificate of Origin, Material Certificate, Certificate of conformity, and Transport papers. Titanium and items of titanium are generally classified under heading 8108 of the Harmonized Tariff Schedule. However, you should check the specific classification with your customs broker. Duties on Chinese-origin items might fluctuate, so check the current rate before you commit. Prices vary by quality, tolerance, finish, inspection, packing, order volume, and freight so compare total landed cost, not just material price. The FDA controls completed medical devices, so raw-material compliance doesn’t take the place of your device clearance.
Separate technical from commercial criteria. Technical criteria include grade, standard, dimensions, surface, mechanical qualities and traceability. Commercial factors include pricing, MOQ, lead time, payment conditions, and delivery. Next, rate each supplier on paperwork, quality system, capacity, dimensional control, communication, delivery history and landing cost. Inspect samples before bulk orders and add independent testing if your risk level warrants it. Look for dependable sourcing, change control, record retention and engineering support. When you search for Dia 10mm Titanium Rod In Medical supplier , it is good to remember that CXMET was founded in 2005, located in China Titanium Valley, occupies 50,000 square meters land, and has more than 80 technicians working for it.
The biggest mistake is that all 10 mm titanium rods are considered equal. Others are accepting 'medical grade' without credentials and conflating raw-material compliance with finished-device clearance. Diameter does not alone verify straightness, cleanliness, fatigue performance or documentation quality. Poor contamination control during cutting and handling might lead to steel particles, cutting fluid residue or mix-up of material. When comparing quotations, be sure each covers cutting, inspection, certification, packing, freight, duties, and remedies for nonconforming items. A lower quotation could only exclude one of these elements.
Before you issue a Purchase Order for any Dia 10mm Titanium Rod In Medical project, always check this list.
A completed checklist puts all four teams on the same page and prevents delays due to missing data.
We customize the rod to your design. Options include custom diameter and length, particular tolerance and mechanical property objectives, pickling, polishing or sandblasting, and machining such as threading, drilling and shaping. Rolling and grinding services for Dia 3–40 mm stock. • Support staff for product and technical concerns. We also provide titanium to maritime, oil and gas, chemical processing, power metallurgy, electronics and coating industries, so we know tough settings. Tell us what you're applying it on and we can suggest a grade and finish to suit.
When ordering a Dia 10mm Titanium Rod In Medical, the customer should specify grade, standard, tolerance, finish and documentation before asking for quotations. Grade 23 is used for implantable parts because to low interstitial restrictions, according to ASTM F136, while Grades 2 and 5 are used for other applications. Titanium differs from stainless steel and cobalt-chrome by having a density of 4.43 g/cm3 , no corrosion and a lower modulus, although other alloys may still be preferred because of cost and stiffness. The performance of the rod after fabrication is affected by the surface polish, machining control and testing such as chemical, ultrasonic and tensile tests. For US imports, documentation, categorization for customs purposes, examination of duty and comparison of landed cost keep surprises at bay. Raw-material certifications are not a substitute for the approval of completed devices, therefore a clear checklist and a comprehensive comparison of suppliers provide a common and verifiable foundation for each procurement for the procurement and engineering teams.
Grade 23 (Ti-6Al-4V ELI) has lower oxygen and iron limits than Grade 5, which improves ductility and fracture toughness. That is why implant-related work usually specifies Grade 23 under ASTM F136.
Yes. We cut to your required length, commonly 100 mm to 1000 mm, and the MOQ is 10 KG. Please state tolerance and end condition in your RFQ.
We provide certificates and test reports for traceability and compliance. Ask for the mill test report, heat number, and certificate of conformity, and confirm any extra tests when you inquire.
Yes. Finish affects cleanability, fatigue behavior, and coating adhesion. We supply polished or machined surfaces and can add pickling or sandblasting. A polished starting surface also makes defects easier to spot.
Send your drawing, grade, quantity, and destination to sales@cxmet.com, and our team will reply with a technical and commercial quote. As an experienced Dia 10mm Titanium Rod In Medical supplier, CXMET offers Grade 23 rod to ASTM F136, Dia 3–40 mm stock, a 10 KG MOQ, custom cutting, and traceable test reports. Visit https://www.cxmet-tech.com/ for more details and request samples today.
1. Journal of the Mechanical Behavior of Biomedical Materials, 2008 – Niinomi, "Mechanical biocompatibilities of titanium alloys for biomedical applications"
2. Progress in Materials Science, 2009 – Geetha et al., "Ti based biomaterials, the ultimate choice for orthopaedic implants – A review"
3. JOM, 2008 – Elias et al., "Biomedical applications of titanium and its alloys"
4. ASM International, 2000 – Donachie, "Titanium: A Technical Guide," 2nd Edition
5. ASTM International, 2013 – ASTM F136, "Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications"
6. International Organization for Standardization, 2016 – ISO 13485, "Medical devices – Quality management systems – Requirements for regulatory purposes"