Dia 10mm Titanium Rod In Medical is used as precision bar stock that manufacturers machine into orthopedic nails, bone screws, spinal components, dental parts, and surgical instrument shafts. The rod itself is not an implant. Engineers turn, drill, thread, and polish it into a finished device, then validate that device for strength, fatigue life, and biocompatibility. Ti-6Al-4V ELI suits this work because it resists corrosion in body fluids, weighs less than steel, and has a stiffness closer to bone. At CXMET, we supply this rod in Grade 23 with custom lengths and ground or polished surfaces.
|
|
|
A 10 mm stick, which is about 0.394 inches, serves as a stable base for the builder. You can turn, drill, thread, and shape it because there is enough material around the outside. If titanium is used in marine, chemical, or oil and gas tools, it doesn't rust. But if titanium is used in medicine, there are stricter rules. The rules are for the finished product, and the rod is the raw material. Its risk class, sterilization method, surface state, licensing, tracking, and grade, as well as its risk tolerance, surface state, and tracking, all affect how well it works. The US FDA still has to look it over after it's done. We use wrought Ti-6Al-4V ELI that meets ASTM F136 at Dia 10mm Titanium Rod In Medical. This is the standard that is used for health care implants.
The stick is cut by the makers into a number of groups for different devices. As bar stock, orthopedic nails and screws are used to fix broken bones and to fix bones that aren't moving. Spinal implants and plates, tooth implants and root posts, and new joints are also made. It is also used to make cutting guides and instrument shafts. Dia 10 mm Titanium Rod in Medical: This is used for intramedullary nails on the humerus or tibia in medical implants. Longitudinal bars in external fixation frames make them stronger without adding metal weight. Before choosing the diameter, engineers look at the structure, the amount of room for machining, the load, the wear, and the final shape. Implants and reused tools need different rules when it comes to keeping them clean and keeping records. With just one stock size, OEMs can make a prototype and then make a lot of them.
Titanium is used in surgery because it is biocompatible, doesn't rust, isn't very dense, and is strong for its weight. Body fluids that are both acidic and salty cover the metal in a thin, stable layer of oxide. Steel is about twice as dense as Ti-6Al-4V, which weighs 4.43 g/cm³. It has a springy stiffness of about 110 GPa, which is less than steel's 200 GPa and more like bone. This helps keep the amount of stress buffering low. Titanium isn't magnetic either, so MRI pictures don't get messed up. But performance can't be promised by a datasheet. Techs use ISO 10993 to check the finished product because machining marks, threads, contamination, and galvanic contact can change the outcomes.
According to ASTM F67, commercially pure titanium grade 2 can be used for some non-load-bearing parts because it doesn't rust, is flexible, and is easy to shape. Stronger parts made of Grade 5, also called Ti-6Al-4V, are used for structures and parts that hold weight. For extra low Grade 5 in the interstitial range, use Grade 23. It can't hold as much oxygen or iron. Because of this, the material is more flexible and less likely to break, and ASTM F136 needs it for surgical implants. We use Grade 23 in our Dia 10mm Titanium Rod In Medical because of this. Make sure to check the chemistry, mechanical properties, heat treatment, and lot tracking of every Grade 5 bar before giving the go-ahead for production.
Look at titanium, cobalt-chromium, and stainless steel side by side to see how much they cost, how dense they are, how strong they are, how stiff they are, how resistant they are to rust and wear, and how easy they are to make. Tin is less dense than steel, and its oxide layer keeps it from breaking, which can happen with steel implants over time. People will always choose stainless steel for simple building projects and cheap tools. Because it is stiff, cobalt-chromium doesn't wear down quickly, but it is thicker and harder to work with. It's not always the same for all metals when a 10 mm diameter is used. The length that isn't supported, the cross-section, the state of the alloy, the surface finish, and the direction of the load all have an effect. You should check the stiffness again if you use our Dia 10mm Titanium Rod In Medical instead of steel, since the lower modulus changes how the part bends. It is made of Grade 23 Ti-6Al-4V ELI and has a diameter of 10 mm. Its length can be customized, but is usually between 100 and 1000 mm. It can be machined, ground, polished, or polished, and it has a tolerance of h7 to h9 or as specified.
As a starting point, these numbers help the design team figure out the strength and allow for cutting. You can see the real lot results in the material test record. Compare your drawing to the report.
| Item | Specification |
|---|---|
| Material | Grade 23 Ti-6Al-4V ELI |
| Diameter | 10 mm |
| Length | Customizable, commonly 100–1000 mm |
| Surface | Ground, polished, or machined |
| Tolerance | h7 to h9 or as specified |
| Standards | ASTM F136, ASTM B348, ISO 5832-3, AMS 4930 |
| Density | 4.43 g/cm³ |
| Tensile strength | ≥ 860 MPa |
| Yield strength | ≥ 795 MPa |
| Elongation | ≥ 14% |
| Hardness | Approx. 35 HRC |
The standards that it meets are ASTM F136, ASTM B348, ISO 5832-3, and AMS 4930. Its density is 4.43 g/cm³, its tensile strength is 860 MPa, its yield strength is 795 MPa, its elongation is 14%, and its hardness is about 35 HRC.
It is very important to keep an eye on the surface state and the size of a machined part in order to make it of good quality. A centerless ground rod makes smooth contact with clamps in external fixation frames. Also, it makes Swiss-type CNC guide bushings fit better. Also, flaws stand out more on a smooth surface. For Dia 10mm Titanium Rod In Medical, buyers should write down the length, chamfers, roundness, straightness, chamfers, and end state using limits that can be measured. The diameter tolerance we offer is between h7 and h9, or as requested. A rough surface on the end implant is usually added later to help the bone grow, so the raw bar is smooth from the start. When the rules for accepting a drawing are clear, there are no arguments at the review.
We always have bars in stock that are 40 mm long and 3 mm wide. The bars are rolled and ground. Customers can ask for different diameters and lengths, as well as certain levels of tolerance, mechanical properties, and surface treatments such as pickling, sandblasting, or polishing. Machining can cut, drill, and shape things, among other things. Only 10 kg of goods can be shipped at a time, and that goes for both trials and production. The weight changes if you choose a different size. In 2005, Shaanxi CXMET Technology Co., Ltd. was set up. Its building is 50,000 square meters and is in China's Titanium Valley. More than 80 technicians work there. That's why each Dia 10mm Titanium Rod in a medical order is backed by it.
Four things are what most people look at before they buy something. Grade 23 has less than 0.13% oxygen and less than 0.25% iron, according to the ICP-OES test. To find holes or other things below the surface that could make the implant fail, AMS 2631 says to use ultrasound. A microstructure review looks for an alpha-beta structure that doesn't have any alpha cases. Tests with a laser micrometer show that the rod is the same diameter all the way along, and ASTM E8 tensile tests show that it is strong. It's also important to keep contamination under control. Cutting fluid leftovers and metal particles can't touch the surface if you use clean tools, clean them properly, and carefully pack your things. We are a supplier, so ask us to show you these records for your lot before you make a deal.
This part talks about ASTM F67, which is pure titanium for medical implants, and ASTM F136, which is cast Ti-6Al-4V ELI. ASTM B348 is a set of rules for bars and billets made of titanium and titanium alloys. AMS 4930 talks about ELI bars made of Ti-6Al-4V, and ISO 5832-3 talks about inserts made of cast Ti-6Al-4V. This standard has to match the grade, shape, condition, and size of the real thing. We list ASTM F136, ASTM B348, ISO 5832-3, and AMS 4930 for our Dia 10mm Titanium Rod in Medical. For medical devices, ISO 13485 is proof that a supplier has a quality system. However, this does not mean that an implant is safe when it is finished. ISO 10993-1 is used to test the end product for biological safety.
There is a certain kind of proof that must be used. There should be chemical and mechanical test results, heat numbers, data on measurement inspection, proof of conformance, records of surface or cleanliness, and information on how the material was packaged in the material test report. Also, find out how changes are managed so you are aware of any material or process changes before they reach your line. For your records and to make sure you follow the rules, we give you test reports and certificates for our Dia 10mm Titanium Rod in Medical. The report, the packing list, and the rod should all have the same heat number. It costs less to find a difference at the receiving end than during device validation. This is because there is a tracking gap at the receiving end.
Read the papers and look at what they can do at the same time. Make sure the ISO 13485 or ISO 9001 certificates still work for the items you need. Find out about the following: keeping records, controlling nonconformances, and cutting, grinding, and polishing, as well as how to clean, cut, grind, and shine. Make sure you look over the export packaging, Incoterms, customs paperwork, and how technical changes are shared for orders coming from other countries. Then, before you sign a long-term contract, make a test order or first-article inspection to make sure everything is in order. Marine, oil, chemical, power metallurgy, medical, electronics, vacuum, and paint are just some of the industries that buy titanium from us, so we know what kind of checking standards they want.
It takes less time to get a quote if the purchase request is clear. Write down the nominal diameter (10 mm), tolerance, roundness, straightness, length, grade, ASTM standard, material condition, surface finish, end requirements, quantity, packaging, and certification needs. There are many things that go into the total cost besides the price per kilogram. These include cutting loss, machine time, inspection, paperwork, freight, material that is rejected, and how well the delivery goes. Check the shipping terms, minimum order, cutting service, stock lengths, lead time, prototype support, and cutting service. You can order as little as 10 kg of Dia 10 mm Titanium Rod in Medical from CXMET. You can also choose from different lengths, most often 100 mm to 1000 mm.
A lot of mistakes keep happening. When people buy titanium for implants, they sometimes mix up industrial titanium with implant-grade titanium, think that all Grade 5 products are safe for implants, or don't notice when the surface is dirty or the packaging is bad. Should the work need to be redone, certificates be lost, sizes not match, or the delivery be late, it may cost more than the price. Also, following the rules for raw materials doesn't mean you don't need to check the finished product, manage risks, make sure it's properly sterilized, or get approval from the government. It is important to write down the exact medical standard, condition, cleanliness standards, requirements for tracking, and acceptance criteria. First, you should look at the price. Next, you should look at the supplier's skills, the quality of their work, and how well they handle changes. With a fully documented bar, there is less technical and business risk.
First, say whether the part can be implanted, used more than once, is instrument-grade, or is thrown away. Then, describe how it will be loaded and how it will be cleaned after being used on a patient for a certain amount of time. Next, pick something that meets the standards for Grade 2, Grade 5, Grade 23, or something else that is okay. Before you look at buyers, write down the standards you have for size, power, wear, surface, and cleanliness. After getting qualified, you have to look over the certificate, test a sample, get approval for the first item, and then try to machine the material. Once production starts, you should keep track of control lots, send out change notices, requalify workers, handle nonconformances, check delivery performance, and do regular source reviews. Sterilization should be done as soon as possible. The Dia 10mm Titanium Rod In Medical can be autoclaved more than once, which is good for instruments and implants that need to be sterilized before surgery and are used more than once.
For medical use, Dia 10mm Titanium Rod In Medical is a semi-finished material that is used to make parts for bones, teeth, instruments, and orthopedics. Titanium works well in these situations because it doesn't rust, isn't too thick, and has a stiffness that is more like bone than steel. Grade 23 Ti-6Al-4V ELI, which is what ASTM F136 says it is, is pure and strong enough for implants. Grade 5 stock is not the same as this. In production, a bar's surface finish, accuracy, quality checks, and records like test results and heat numbers determine whether it works or not. If you only look at price or use industrial titanium as implant grade, there are risks. Following the rules for raw materials is never the same as checking the finished product, so selection links checking the application, grade, standard, and supplier.
When it comes to oxygen and iron, Grade 23 (Ti-6Al-4V ELI) is not as bad as Grade 5. Based on ASTM F136, these limits make it more bendable and less likely to break. This is why they are needed for surgical implants. Our rod is made from Grade 23 titanium, and it comes with test results and papers to help you keep track of it.
Oh no, diameter is the only way to show size. If a rod is good for an implant, it depends on its grade, specifications, certification, and ability to be tracked. The finished gadget still needs to be checked for safety, tried, approved by the government, and verified. Keep in mind that the rod is only a known piece of material and not an approved implant.
As asked, we give you h7 to h9 or more. For a Swiss-type CNC lathe, the bar needs to fit the guide nut when it feeds, so pick a smaller ground tolerance. Parts that can be machined with more freedom work better when the specs are not too tight. We'll tell you what the right range is after you send us your drawing.
Looking for a Dia 10mm Titanium Rod in a medical supplier that offers custom lengths, ground surfaces, and documented traceability? CXMET stocks titanium rods in stock that range in size from 3 to 40 mm. When you order 10 kg or more, the rod comes in a standard wooden case. Email sales@cxmet.com with the grade, tolerance, length, amount, and location of the metal you want to buy to get a technical price. Our full line of titanium goods can be seen at https://www.cxmet-tech.com/.
1. ASTM International, ASTM F136 – Standard Specification for Wrought Titanium-6A luminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications, 2021
2. ASTM International, ASTM B348 – Standard Specification for Titanium and Titanium Alloy Bars and Billets, 2019
3. ASTM International, ASTM F67 – Standard Specification for Unalloyed Titanium, for Surgical Implant Applications, 2017
4. Niinomi, M., Mechanical Biocompatibilities of Titanium Alloys for Biomedical Applications, Journal of the Mechanical Behavior of Biomedical Materials, 2008
5. Geetha, M., Singh, A.K., Asokamani, R., Gogia, A.K., Ti-Based Biomaterials, the Ultimate Choice for Orthopaedic Implants—A Review, Progress in Materials Science, 2009
6. International Organization for Standardization, ISO 10993-1 – Biological Evaluation of Medical Devices, Part 1, 2018
YOU MAY LIKE